Share:


HannYa 2 Zone Type Thermal Shock Test Chamber High and Low Temperature Reservation Cabinet (HY-TS-225)

HannYa 2 Zone Type Thermal Shock Test Chamber High and Low Temperature Reservation Cabinet

Machine introduction:

Air Cooled 2 Zone Type Thermal Shock Test Chamber High and Low Tempearture Reservation Cabinet is metal, plastic, rubber, electronics and other industries necessary testing equipment. For the continuous exposure to extremely high temperature, very low temperature environment, instant exposure of the material structure or composite material tolerance, can be detected in the shortest possible time due to thermal expansion and contraction caused by chemical or physical damage.

 Air Cooled 2 Zone Type Thermal Shock Test Chamber High and Low Tempearture Reservation Cabinet meets today's environmental stress screening requirements and is proven in installations around the world. It's an economical way to achieve ESS or thermal shocks for rapid component temperature changes.

The thermal shock chamber of this type is provided with three dampers, i.e., one for opening or closing the gas outlet and intake of the high-temperature air conditioning unit, another for the air outlet and inlet of the outside air supplying unit, and another for the gas outlet and intake of the low-temperature air conditioning unit.

Standards:

1. GB/T2423.1-1989
2. GB/T2423.2-1989
3. GB/T2423.22-1989
4. GJB150.5-86
5. GJB360.7-87
6. GJB367.2-87 405
7. SJ/T10187-91Y73
8. SJ/T10186-91Y73
9. IEC68-2-14
10. GB/T 2424.13-2002
11. GB/T 2423.22-2002
12. QC/T17-92
13. EIA 364-32

Schematic The Diagram of Working Principle

The high and low temperature thermal shock test chamber is necessary test equipment in the material industry such as metal plastic, rubber, electronic ,etc and is used for testing the material structure or the composite material. The chemical cahnge or physical damage caused by thermal expansion and contraction of the sample can be detected in shortest time. It is divided into two-zone type and three-zone type, and the difference lies in that the test method and the internal structure are different and the product conforms to the requirements of GB/T2423.1-2008 Test A, GB/T2423.2-2008 Test B, GB-T10592-2008, GJB150.3198. GJB360A-96 method 107 temperature impact test

Specifications:

Model HY-42 HY-80 HY-150 HY-225 HY-300
Inner Size(cm) 40×35×30 40×50×40 50×60×50 50×75×60 100×60×50
Temperature Range

High temperature: +60°C~+150°C (or 180°C)

Low temperature: -10°C~-40°C (or -40°C, -50°C,-60°C, -70°C)

Temperature Deviation Less than ±2°C
Temperature Conversion Time Less than 10S
Temperature Recovery Time Less than 5min
Test method 2 zone type or 3 zone type
Cooling System Water-cooled / air-cooled(small chambers only)
Power AC380V/50HZ Three-phase







 Inquiry - HannYa 2 Zone Type Thermal Shock Test Chamber High and Low Temperature Reservation Cabinet (HY-TS-225)